Product Features
Four filtered functions
Product Technical Spec.
Overall Length:
3.374 inches
Body Length:
3.062 inches
Body Height:
1.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.500 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
Operating Tempurature Range:
-55.0/+100.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.0 1st radio interference
Operating Current Rating Per Function In Amps:
1.0 3rd radio interference
Operating Current Rating Per Function In Amps:
1.0 4th radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
Maximum Voltage Drop Per Function:
1.25 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
1.25 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
1.25 volts ac 3rd radio interference
Maximum Voltage Drop Per Function:
1.25 volts ac 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Full Load Insertion Loss Frequencies In Megahertz:
0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
7.0 and 7.0 and 7.0 and 7.0 and 60.0 and 60.0
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 threaded hole
Features Provided:
Moisture resistant and shock resistant
Functional Terminal Type And Quantity:
4 tab, solder lug input 1st function
Functional Terminal Type And Quantity:
4 tab, solder lug output 2nd function
Maximum Dielectric Withstanding Ac Rms Voltage:
250.0 volts at sea level
Operating Voltage Rating And Type Per Function:
125.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
125.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
125.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
125.0 volts ac 1st radio interference 1st function
Thread Size:
0.138 inches
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
12.000 ounces
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC